Shijiazhuang ultimate technology solutions co.,ltd

Pumping The Water , Pumping Our Honor

Manufacturer from China
Active Member
5 Years
Home / Products / Magnetic Centrifugal Pump /

CQB Nitric Acid Resistant Pump Mini Magnetic Drive Centrifugal Pump

Contact Now
Shijiazhuang ultimate technology solutions co.,ltd
City:shijiazhuang
Province/State:hebei
Country/Region:china
Contact Person:MrRichard
Contact Now

CQB Nitric Acid Resistant Pump Mini Magnetic Drive Centrifugal Pump

Ask Latest Price
Video Channel
Brand Name :Gempump
Model Number :CQB65-40-250F
Certification :ISO9001 CE
Place of Origin :China
MOQ :1 set
Price :1000 USD/SET
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :1000 SET/Month
Delivery Time :5-8 working days
Packaging Details :Ply wooden box
Product :Acid Proof Magnetic Transfer Pump
Place of Orign :China
Application :Aicd,Alkali,Wastewater Transport
Warranty :2 year
Lead time :10 days
Motor voltage :AC220V,AC380V,AC415V
Pump material :FEP, PFA, PTFE, PVDF, PP
Power :Electric Motor
Structure :Single Stage Pump
Seal :Mechanical seal,no leakage
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

CQB Nitric Acid Resistant Pump Mini Magnetic Drive Chemical Centrifugal Pump

Magnetic pump is a horizontal, sealless centrifugal pump with permanent magnetic coupling, compliant with ASME B73.3-2003,
sealless pump standard for volatile chemical, inflammable, aggressive, explosive and toxic liquids.

Pumping Liquid:
- Strong corrosive liquids
- Aggressive, explosive and toxic liquids
- Volatile chemicals
- Flammable liquids
- Difficult-to-seal liquids

1, CQB magnetic drive centrifugal pump product overview:

CQB magnetic drive centrifugal pump (referred to as magnetic pump) is usually composed of motor, magnetic coupling and corrosion-resistant centrifugal pump. When the motor drives the outer magnetic steel of the magnetic coupling to rotate, the magnetic line of force passes through the gap and the isolation sleeve and acts on the inner magnetic steel, so that the pump rotor and the motor rotate synchronously and transmit the torque without mechanical contact. At the power input end of the pump shaft, because the liquid is sealed in a stationary isolation sleeve, there is no dynamic seal, so there is no leakage at all.

CQB series magnetic pump is a new type of completely leak free and corrosion-resistant pump developed by the national joint design group of magnetic pump. Its technical and economic indexes are equivalent to the level of similar foreign products at the end of 1980s.

2, CQB magnetic drive pump installation and use:

2.1. The magnetic drive pump should be installed horizontally, not vertically. The plastic pump body should not bear the weight of the pipeline. For the occasion of vertical installation with special requirements, the motor must face up.

2.2. When the suction liquid level of CQB magnetic pump is higher than the pump axis line, open the suction pipe valve before starting the magnetic drive pump. If the suction liquid level is lower than the pump axis line, the pipe shall be equipped with bottom valve.

2.3. The magnetic drive pump should be checked before use. The motor fan blade should rotate flexibly without jamming and abnormal sound. All fasteners should be tightened.

2.4. Check whether the rotation direction of the motor is consistent with the steering mark of the magnetic pump.

2.5. After the motor of the magnetic drive pump is started, slowly open the discharge valve. After the pump enters the normal working state, adjust the discharge valve to the required opening.

2.6. Before the magnetic drive pump stops working, the discharge valve should be closed first, and then the suction pipe valve should be closed.

3, Precautions for use of CQB magnetic drive pump:

3.1. Because the cooling and lubrication of the magnetic pump bearings depend on the medium to be transported, it is absolutely forbidden to run idly, and at the same time, it can avoid the space-time running caused by the restart after the power failure in the middle of the work.

3.2. If there are solid particles in the medium to be transported, the inlet of the magnetic drive pump should be equipped with a filter screen; if there are ferromagnetic particles, a magnetic filter should be added.

3.3. The ambient temperature of magnetic drive pump in use should be less than 40 ℃, and the temperature rise of motor should not exceed 75 ℃.

3.4. The medium and temperature to be transported by the magnetic drive pump shall be within the allowable range of the pump material (see the attached table for details). The service temperature of the engineering plastic pump is less than 60 ℃, the service temperature of the metal pump is less than 100 ℃, the conveying pressure is not more than 0.2MPa, the maximum working pressure is 1.6Mpa, the density is not more than 1600kg / m3, and the particle size is not more than 30 × 10-6m2 / s.

3.5. The magnetic drive pump should be cleaned in time after use for the medium whose conveying liquid is easy to precipitate and crystallize, so as to drain the liquid in the pump.

3.6. After the magnetic drive pump runs for 100 hours, the bearing and end moving ring should be disassembled and inspected for wear, and the wearing parts that are not suitable for reuse should be replaced.

3.7. The internal and external magnetic couplings of CQB magnetic pump are made of high-performance permanent magnetic materials, which may cause potential harm to the following devices. Please keep the following devices away from this series of pumps. For example: cardiac pacemaker, Xinyong card and other magnetic cards, calculator, computer disk, watch, etc.

CQB Nitric Acid Resistant Pump Mini Magnetic Drive Centrifugal Pump

4, Performance Parameters of CQB Magnetic Drive Pump:

Pump model Flow rate
(m3/h)
Lift/Head
(m)
Speed
(r/min)
Power
(kw)
CQB32-20-125 3.2 20 2900 1.5
CQB32-20-160 32 2.2
CQB40-25-105 6.3 12.5 1.1
CQB40-25-125 20 2.2
CQB40-25-160 32 3
CQB40-25-200 50 5.5
CQB50-40-85 12.5 8 1.1
CQB50-32-105 12.5 1.5
CQB50-32-125 20 3
CQB50-32-160 32 4
CQB50-32-200 50 7.5
CQB50-32-250 80 18.5
CQB65-50-125 25 20 4
CQB65-50-160 32 7.5
CQB65-40-200 50 15
CQB65-40-250 80 22
CQB80-65-125 50 20 7.5
CQB80-65-160 32 15
CQB80-50-200 50 22
CQB80-50-250 80 37
CQB100-80-125 100 20 15
CQB100-80-160 32 22
CQB100-65-200 50 37
CQB100-65-250 80 55
CQB150-150-200 200 50 55
CQB200-200-400 400 32 1450 75

Inquiry Cart 0